Part Number Hot Search : 
P0603 MF430ST NSR2N SI6543DQ B59501 47M10 10020 RPS250E
Product Description
Full Text Search
 

To Download XRT7295AE03 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 XRT7295AE
E3 (34.368Mbps) Integrated line Receiver
March 2003
FEATURES
l
APPLICATIONS
l l l l l
Fully Integrated Receive Interface for E3 Signals Integrated Equalization (Optional) and Timing Recovery Loss-of-Signal and Loss-of-Lock Alarms Variable Input Sensitivity Control 5V Power Supply Compliant with G703, G.775 and G.824 Specifications
Interface to E3 Networks CSU/DSU Equipment PCM Test Equipment Fiber Optic Terminals Multiplexers
l
l l l l
GENERAL DESCRIPTION The XRT7295AE E3 Integrated Line Receiver is a fully integrates receive interface that terminates a bipolar E3 (34.3684 Mbps) signal transmitted over coaxial Cable. This device can be used with the XRT7296 Integrated Line Transmitter (see Figure 10),
The device provides the functions of receive equalization (optional) automatic gain control (AGC), clock recovery and data re-timing, loss of signal and loss-of frequency lock detection. The digital system interface is a dual-rail with received positive and negative 1s appearing as unipolar digital signals on separate output leads. The on-chip equalizer is designed for cable
losses of 0 to 15dB. The receive input has a variable input sensitivity control, providing three different sensitivity settings. High input sensitivity allows for significant amounts of flat loss or for use with input signals at the monitor level. Figure 1 shows the block diagram of the device. The XRT7295AE is manufactured by using linear CMOS technology. The XRT7295AE is available in a 20-pin plastic SOJ package for surface mounting. A pin compatible version is available for DS3 or STS-1 applications. Please refer to the XRT7295AT data sheet
ORDERING INFORMATION
Operating Temperature Range -40C to +85C
Part No. XRT7295AEIW
Package 20 J-lead 300 MIL JEDEC SOJ
Rev. 2.0.0 EXAR Corporation, 48720 Kato Road, Fremont, CA 94538 * (510) 668-7000 * FAX (510) 668-7017
XRT7295AE
Figure 1. Block Diagram
PIN CONFIGURATION
Rev. 2.0.0
2
XRT7295AE
PIN DESCRIPTION
Pin # 1 2 3,6 4,5 7 8 9 10 11 12 13 Symbol GNDA RIN TMC1-TMC2 LPF-1-LPF-2 RLOS RLOL GNDD GNDC VDDD VDDC EXCLK I I I I O O Type Description Analog Ground. Receive Input. Unbalanced analog receive input Test Mode Control 1 and 2. Internal test modes are enabled within the device by using TMC1 and TMC2. Users must tie these pins to the ground plane. PLL Filter 1 and 2. An external capacitor (0.1F +/-20%) is connected between these pins (See Figure 3). Receive Loss-of-Signal. This pin is set high on loss of signal at the receive input. Receive PLL Loss-of-Lock. This pin is set high on loss of PLL frequency lock. Digital Ground for PLL Lock. Ground lead for all circuitry running synchronously with PLL clock. Digital Ground for EXCLK. Ground lead for all circuitry running synchronously with EXCLK. 5V Digital Supply (+/-10%) for PLL Clock. Power for all circuitry running synchronously with PLL clock. 5V Digital Supply (+/-10%) for EXCLK. Power for all circuitry running synchronously with EXCLK. External Reference Clock. A valid E3 (34.368MHz +/-100ppm) clock must be provided at this input. The duty cycle of EXCLK, referenced to VDD/2 levels, must be 40%-60%. Receive Clock. Recovered clock signal to the terminal equipment. Receive Negative Data. Negative pulse data output to the terminal equipment. Receive Positive Data. Positive pulse data output to the terminal equipment. Output In-Circuit Test Control (Active-Low). If ICT is forced low, all digital output pins (RCLK, RPDATA, RNDATA, RLOS, RLOL) are placed in a highimpedance state to allow for in-circuit testing. Receive Equalization Bypass. A high on this pin bypasses the internal equalizer. A low places the equalizer in the data path. Loss-of-Signal Threshold Control. The voltage forced on this pin controls the input loss-of-signal threshold. Three settings are provided by forcing the GND, VDD/2, or VDD at LOSTHR. 5V Analog Supply (+/-10%).
14 15 16 17
RCLK RNDATA RPDATA ICT
O O O I
18 19
REQB LOSTHR
I I
20
VDDA
Rev. 2.0.0
3
XRT7295AE
DC ELECTRICAL CHARACTERISTICS Test Conditions: -40C < TA < +85C, VDD = 5V +/-10% Typical values are for VDD =5.0V, 25C, and random data. Maximum values for VDD = 5.5V at 85C all 1s data.
Symbol Parameter Electrical Characteristics IDD Power Supply Current REQB=0 REQB=1 82 79 106 103 mA mA Min. Typ. Max. Unit Conditions
Logical Interface Characteristics VIL VIH Input Voltage Low High Output Voltage Low High Input Capacitance Load Capacitance Input Leakage -10 GNDD VDDD -0.5 GNDD VDDD -0.5 0.5 VDDD V V
VOL VOH CI CL IL
0.4 VDDD 10 10 10
V V pF pF A
-5.0mA 5.0mA
0.02 10 -50 Note: Specifications are subject to change without notice.
0.5 100 -5
mA A A
-0.5 to VDD +0.5V (all input pins except 2 and 17) 0V (pin 17) VDD (pin 2) GND (pin 2)
ABSOLUTE MAXIMUM RATINGS Power Supply ....................... -0.5V to +6.5V
Storage Temperature ............ Voltage at any Pin ................ Power Dissipation ................. -40C to +125C -0.5V to VDD +0.5V 700mW
Maximum Allowable Voltages (RIN) with Respect to GND .......... -0.5 to +5V
Rev. 2.0.0
4
XRT7295AE
XRT7295AE XRT7296
XRT7296
Transmitter
XRT7295AE
Transmitter
Figure 2. Application Diagram
SYSTEM DESCRIPTION Receive Path Configurations The diagram in Figure 2 shows a typical system application for the XRT7295AE. In the receive signal path (see Figure 1), the internal equalizer can be included by setting REQB=0 or bypass by setting REQB=1. The equalizer bypass option allows easy interfacing of the XRT7295AE into systems already containing the external equalizers. Figure 3 illustrates the receive path option for two separate cases.
In case 1, the signal from the coaxial cable feeds directly into the RIN input. In this mode, the user should set REQB=0, engaging the equalizer in the data path if the cable loss is greater than 6dB. If the cable loss is less than 6dB, the equalizer is bypassed by setting the REQB=1. In case 2, an external line and equalizer network precedes the XRT7295AE. In this mode, the signal at RIN is already equalized, and the on-chip equalizer should be bypassed by setting REQB1=1. In both cases, the signal at RIN must meet the amplitude limits described in Table 1. The recommended receive termination is also shown in Figure 3. The 75 resistor terminates the coaxial cable with its characteristic impedance. In Figure 3 case 2, if the fixed equalizer includes the line termination, the 75 resistor is not required. The signal is AC coupled through the 0.01F capacitor to RIN. The DC bias at RIN is generated internally. The input capacitance at the RIN pin is typically 2.8pF (SOJ package).
Pulse Mask at the 34.368 Mbps Interface Table 2 shows the pulse specifications at the transmitter output post and Figure 4 shows the pulse mask requirement for E3 as recommended in G.703.
Minimum Signal REQB 0 LOSTHR 0 VDD/2 VDD 1 0 VDD/2 VDD NOTES: 1 2 3 Maximum input amplitude under all conditions is 1.1 Vpk. The SOJ package performance is enhanced by decreased package parasitics. Although system designers typically use power in dBm to describe input levels, the XRT7295AE responds to peak input signal amplitude. Therefore, the XRT7295AE input signal limits are given in mV pk. SOJ2 80 60 40 80 80 80 DIP 115 85 60 115 115 115 Unit3 mV pk mV pk mV pk mV pk mV pk mV pk
Table 1. Receive Input Signal Amplitude Requirements
Rev. 2.0.0
5
XRT7295AE
Line Termination and Input Capacitance
The recommended receive termination is shown in Figure 3. The 75 resistor terminates the coaxial cable with its characteristic impedance. The 0.01F capacitor to RIN couples the signal into the receive input without disturbing the internally generated DC bias level present on RIN. The input capacitance at the RIN pin is 2.8pF.
External Loop Filter Capacitor
Figure 3 shows the connection to an external 0.1F capacitor at the LPF1/LPF2 pins. This capacitor is part of the PLL filter. A non-polarized, low-leakage capacitor should be used. A ceramic capacitor with the value 0.1F +/-20% is acceptable.
XRT7295AE
XRT7295AE
Figure 3. Receiver Configuration
TIMING RECOVERY Output Jitter
The total jitter appearing on the RCLK output during normal operation consists of two components. First,
some jitter appears on RCLK because of jitter on the incoming signal. (The following section discussed the jitter transfer characteristic, which describes the relationship between input and output jitter.) Second, noise sources within the XRT7295AE or noise sources that are coupled into the device through the power supplies create jitter on RCLK. The magnitude of this
Rev. 2.0.0
6
XRT7295AE
internally generated jitter is a function of the PLL bandwidth, which in turn is a function of the input 1s density. For higher 1s densities, the amount of generated jitter decreases. Generated jitter also depends on the quality of the power supply bypassing networks used. Figure 8 shows the suggested bypassing network, and Table 3 lists the typical generated jitter performance achievable with this network.
Figure 4. Pulse Mask at the 34.368 Mbit/s Interface
Parameter Pulse Shape (Nominally Rectangular) Pair(s) in Each Direction Test Load Impedance Nominal Peak Voltage of a Mark (Pulse) Peak Voltage of a Space (No Pulse) Nominal Pulse Width Ratio of the Amplitudes of Positive and Negative Pulses at the Center of a Pulse Interval Ratio of the Widths of Positive and Negative Pulses at the Nominal Half Amplitude
Value All marks of a valid signal must conform with the mask (see Figure 4), irrespective of the sign One coaxial pair 75 Resistive 1.0V 0V +/-0.1V 14.55ns 0.95 to 1.05 0.95 to 1.05
Table 2. E3 Pulse Specification at the Transmitter Output Port
Rev. 2.0.0
7
XRT7295AE
Jitter Transfer Characteristic
The jitter transfer characteristic indicates the fraction of input jitter that reaches the RCLK output as a function of input jitter frequency. Table 3 shows important jitter transfer characteristic parameters. Figure 6 also shows a typical characteristic , with the operating conditions as described in Table 3.
Parameter Generated Jitter1 All-1s patter Repetitive 1000 pattern Jitter Transfer Characteristic2 Peaking f3dB Notes: 1 Repetitive input data pattern at nominal E3 level with VDD=5V TA=25C. 2 Repetitive 1000 input at nominal E3 level with VDD=5V, TA=25C. 0.05 205 0.1 dB kHz 1.0 1.5 ns peak-to-peak ns peak-to-peak Typ. Max. Unit
Jitter Accommodation
Under all allowable operating conditions, the jitter accommodation of XRT7295AE exceeds limits for error-free operation (BER < 1E-9). The typical (VDD = 5V, T = 25C, E3 nominal signal level) jitter accommodation of the device is shown in Figure 6.
Figure 5. Typical PLL Jitter Transfer Characteristics
Table 3. Generated Jitter and Jitter Transfer Characteristics
Figure 6. Lower Limit of Maximum Tolerable Input Jitter at 34.368Mbps
Rev. 2.0.0
8
XRT7295AE
False-Lock Immunity
False-lock is defined as the condition where a PLL recovered clock obtains stable phase-lock at a frequency not equal to the incoming data rate. The XRT7295AE uses a combination frequency/phaselock architecture to prevent false-lock. An on-chip frequency comparator continuously compares the EXCLK reference to the PLL clock. If the frequency difference between the EXCLK and PLL clock exceeds approximately +/-0.5% of EXCLK, correction circuitry acts to force the reacquisition of the proper frequency and phase.
Data Rate REQB LOSTHR 0 E3 34.368 Mbps 1 0 VDD/2 VDD 0 VDD/2 VDD Notes: 1 The RLOS alarm is an indication of the presence of an input signal, not a bit error rate indication. Table 1 gives the minimum input amplitude needed for errorfree operation (BER<1E-9). Independent of the RLOS state, the device will attempt to recover correct timing and data. The RLOS low-to-high transition typically occurs 1dB below the high-to-low transition. Threshold MIN Max 60 40 25 45 30 20 220 145 90 175 115 70 Unit mV pk mV pk mV pk mV pk mV pk mV pk
Acquisition Time
If a valid input signal is assumed to be already present at RIN, the maximum time between the application of device power and error-free operation is 20ms. If power has already been applied, the interval between the application of valid data and error-free operation is 4ns.
2
Analog Detection
The analog LOS detector monitors the peak input signal amplitude. RLOS makes a high-to-low transition (input signal regained) when the input signal amplitude exceeds the loss-of-signal threshold defined in Table 4. The RLOS low-to-high transition (input signal loss) occurs at a level typically 1.0dB below the high-to-low transition level. The hysteresis prevents RLOS chattering. Once set, the RLOS alarm remains high for at least 32 clock cycles, allowing for system detection of a LOS condition without the use of an external alarm latch. To allow for varying levels of noise and crosstalk in different applications, three loss-of-signal threshold settings are available using the LOSTHR pin. Setting LOSTHR = VDD provides the lowest loss-of-signal threshold; LOSTHR = VDD/2 (can be produced using two 50k +/-10% resistor as a voltage divider between VDDD and GNDD) provides an intermediate threshold. LOSTHR = GND provides the highest threshold. The LOSTHR pin must be set to its desired value at power up and must not be changed during operation.
Loss-of-Lock Indication
As previously stated, the PLL acquisition aid circuitry monitors the PLL clock frequency relative to the EXCLK frequency. The acquisition circuit also monitors the resumed data to detect possible phase-lock which is 180 out of a normal phase alignment. The RLOL alarm is activated if either or both of the following conditions exist: - The difference between the PLL clock and the EXCLK frequency exceeds approximately +/0.5%. - The retimed data is 180 out of a normal phase alignment. A high RLOL output indicates that the acquisition circuit is working to bring the PLL into proper frequency lock. RLOL remains high until frequency lock has occurred; however, the minimum RLOL pulse width is 32 clock cycles.
Loss-of-Signal Detection
Figure 1 shows that analog and digital methods of lossof-signal (LOS) detection are combined to create the RLOS alarm output. RLOS is set if either the analog or digital detection circuitry indicates LOS has occurred.
Rev. 2.0.0
9
XRT7295AE
Figure 7. Test Set-up for Interference Immunity Requirements
Digital Detection
In addition to the signal amplitude monitoring of the analog LOS detector, the digital LOS detector monitors the recovered data 1s density. The RLOS alarm goes high if 160 +/-32 or more consecutive bits. The alarm goes low when at least eight 1s occur in a a string of 32 consecutive bits. This hysteresis minimizes RLOS chattering and guarantees a minimum RLOS pulse width of 32 clock cycles.
NOTE: RLOS chatter can still occur. When REQB=1, input signal levels above the analog LOS threshold can still be low enough to result in a high but error rate. The resultant data stream (containing errors) can temporarily activate the digital LOS detector, ad RLOS chatter can occur. Therefore, RLOS should not be used as a bit error rate monitor. RLOS chatter can also occur when RLOL is activated (high).
Parameter Attenuator
Min. -20
Typ. -16
Max.
Unit dB
Table 5. Interference Requirement
Interference Immunity
The XRT7295AE complies with the interference test detailed in Figure 7 and Table 5. The two data generators are non-synchronous.
In-Circuit Test Capability
When pulled low, the ICT pin forces all digital output buffers (RCLK, RPDATA, RNDATA, RLOS, RLOL pins) to be placed in a high output impedance state, This feature allows in-circuit testing to be done on neighboring devices without concern for XRT7295AE buffer damage. When forced high, the ICT pin does not affect device operation. An internal pull-up device (nominally 50 k) is provided on this pin; therefore, users can leave this pin open for normal operation. This is the only pin for which the internal pull-up/pull-down is provided.
Phase Hits
In response to a 180 phase hit in the input data, the XRT7295AE returns to error-free operation in less than 2ms. During the reacquisition time, RLOS may be temporarily indicated.
Recovered Clock and Data Timing
Table 6 and Figure 9 summarize the timing relationships between the high-speed logic signals RCLK, RPDATA, and RNDATA. All duty cycle and timing relationships are referenced to VDD/2 threshold level. RPDATA and RNDATA change on the rising edge of RCLK and are valid during the falling edge of RCLK. A positive pulse at RIN creates a high level on RPDATA and a low level on RNDATA. A negative pulse creates a high level on RNDATA and a low level on RPDATA, and a received zero produces low levels on both RPDATA and RNDATA.
BOARD LAYOUT CONSIDERATIONS Power Supply Bypassing
Figure 8 illustrates the recommended power supply bypassing network. A 0.1F capacitor bypasses the digital supplies. The analog supply VDDA is bypassed by using a 0.1F capacitor and a shield bead that removes significant amounts of high-frequency noise generated by the system and by the device logic. Good quality, high-frequency (low lead inductance) capacitors should be used. Finally, it is most important that all ground connections be made to a low-impedance ground plane.
Rev. 2.0.0
10
XRT7295AE
Receive Input
The connections to the receive input pin, RIN, must be carefully considered. Noise-coupling must be minimized along the path from the signal entering the board to the input pin. Any noise coupled into the XRT7295AE input directly degrades the signal-tonoise ratio of the input signal.
PLL Filter Capacitor
The PLL filter capacitor between pins LPF1 and LPF2 must be placed as close to the chip as possible. The LPF1 and LPF 2 pins are adjacent, allowing for short lead lengths with no crossovers to the external capacitor. Noise-coupling into the LPF1 and LPF2 pins may degrade PLL performance.
Note: 1 Recommended shield beads are the Fair-Rite 2643000101 or the Fair-Rite 2743019446 (surface mount).
Handling Precautions
Figure 8. Recommended Power Supply Bypassing Network Although protection circuitry has been design into this device, proper precautions should be taken to avoid exposure to Electrostatic Discharge (ESD) during handling and mounting.
COMPLIANCE SPECIFICATIONS
Compliance with CCITT Recommendations G.703, G.775, and G.824, 1988.
Rev. 2.0.0
11
XRT7295AE
TIMING CHARACTERISTICS Test Conditions: All timing characteristics are measured with 10pF loading, -40C < TA < 85C, VDD = 5V +/-10%
Symbol tRCH1RCH2 tRCL1RCL1 TRCGRD Parameter Clock Rise Time (10%-90%) Clock Fall Time (10% to 90% Receive Propagation Delay Clock Duty Cycle
1
Min.
Typ.
Max. 3.5 2.5
Unit ns ns ns %
0.6 45 50
3.7 55
Note: 1 The total delay from RIN to the digital outputs RPDATA and RNDATA is three RCLK clocks.
Table 6. System Interface Timing Characteristics (See Figure 9)
Figure 9. Timing Diagram for System Interface
Rev. 2.0.0
12
XRT7295AE
XRT7295AE
XRT7296
Figure 10. Evaluation System Schematic
Rev. 2.0.0
13
XRT7295AE
Rev. 2.0.0
14
XRT7295AE
NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary depending upon a user's specific application. While the information in this publication has been carefully checked; no responsibility, however, is assumed for in accuracies. EXAR Corporation does not recommend the use of any of its products in life support applications where the failure or malfunction of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances. Copyright 2003 EXAR Corporation Datasheet March 2003 Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited. Rev. 2.0.0
15


▲Up To Search▲   

 
Price & Availability of XRT7295AE03

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X